VDIF312312
恒温器电源要求:19-30 Vac 50或60 Hz;2 VA 2级工作条件:0°C至50°C(32°F至122°F)0%至95%R.H.非冷凝存储条件:-30°C至50°C(-22°F至122°F)0%至95%R.H.非冷凝温度传感器:本地10 K NTC热敏电阻分辨率:±0.1°C(±0.2°F)控制精度:温度:±0.5°C(±0.9°F)@21°C(70°F)典型校准湿度:±5%RH从20到50至90°F(10至32°C)时的0%相对湿度占用和未占用设定点范围冷却:12.0至37.5°C(54至100°F)占用和未占用设定点范围加热:4.5°C至32°C(40°F至90°F)房间和室外温度显示-40°C至50°C(-40°F至122°F)房间温度范围控制的比例带:冷却和加热:1.8°C(3.2°F)二进制输入:干燥端子BI1、BI2和UI3与Scom输出之间的触点额定值:双向晶闸管输出:30 Vac,1安培。大,3安培。冲击模拟:0至10 Vdc至2KΩ 小电阻省煤器模拟输出额定值:0至10 Vdc至2Kohms小电阻省煤器模拟输出精度:±3%典型线规:大18量规,建议尺寸22量规:4.94“x 3.38”x 1.13”近似装运重量:0.75 lb(0.34 kg)系列控制装置仅用作操作控制装置,不是安全装置。这些仪器在装运前经过了严格的测试和验证,以确保在现场正确可靠地运行。当控制故障可能导致人身伤害和/或财产损失时,用户/安装人员/电气系统设计师应负责安装安全装置(如继电器、流量开关、热保护等)和/或报警系统,以保护整个系统免受此类灾难性故障的影响。篡改设备或误用设备将导致保修无效。



Thermostat power requirements: 19-30 Vac 50 or 60 Hz; 2 VA Class 2 Operating conditions: 0 °C to 50 °C ( 32 °F to 122 °F ) 0% to 95% R.H. non-condensing Storage conditions: -30 °C to 50 °C ( -22 °F to 122 °F ) 0% to 95% R.H. non-condensing Temperature sensor: Local 10 K NTC thermistor Resolution: ± 0.1 °C ( ± 0.2 °F ) Control accuracy: Temp: ± 0.5 ° C ( ± 0.9 °F ) @ 21 °C ( 70 °F ) typical calibrated Humidity: ± 5% RH from 20 to 0% RH at 50 to 90°F (10 to 32 °C) Occupied and unoccupied setpoint range cooling: 12.0 to 37.5 °C ( 54 to 100 °F ) Occupied and unoccupied setpoint range heating: 4.5 °C to 32 °C ( 40 °F to 90 °F ) Room and outdoor air temperature display -40 °C to 50 °C ( -40 °F to 122 °F ) Proportional band for room temperature range control: Cooling & Heating: 1.8°C ( 3.2°F ) Binary inputs: Dry contact across terminal BI1, BI2 & UI3 to Scom Outputs rating: Triac output: 30 Vac, 1 Amp. Maximum, 3 Amp. in-rush Analog: 0 to 10 Vdc into 2KΩ resistance min. Economizer analog output rating: 0 to 10 Vdc into 2Kohms resistance min. Economizer analog output accuracy: ± 3% typical Wire gauge: 18 gauge maximum, 22 gauge recommended Dimensions: 4.94” x 3.38” x 1.13” Approximate shipping weight: 0.75 lb ( 0.34 kg )series controls are for use as operating controls only and are not safety devices. These instruments have undergone rigorous tests and verifications prior to shipment to ensure proper and reliable operation in the field. Whenever a control failure could lead to personal injury and/or loss of property, it becomes the responsibility of the user / installer / electrical system designer to incorporate safety devices ( such as relays, flow switch, thermal protections, etc…) and/or alarm system to protect the entire system against such catastrophic failures. Tampering with the device or misapplication of the device will void the warranty.
相关产品