欢迎来到瑞昌明盛自动化设备有限公司官网!

产品展示
联系我们

联系人:麦女士

手机:+86 15270269218

电话:

Q Q:3136378118

邮箱:stodcdcs@gmail.com

地址:江西省九江市瑞昌市东益路23号赛湖农商城401号

1X00126H02重量颜色
1X00126H02重量颜色
1X00126H02重量颜色
1X00126H02重量颜色
1X00126H02重量颜色
1X00126H02重量颜色

型号:1X00126H02

类别:EMERSON

联系人:麦女士

手机:+86 15270269218

电话:+86 15270269218

Q Q:3136378118

邮箱:stodcdcs@gmail.com

地址:江西省九江市瑞昌市东益路23号赛湖农商城401号


在线咨询


1X00126H02
以太网输入/输出卡(EIOC)2021 4月www.emerson。com/deltav 11认证EIOC可获得以下认证(有关每种产品的确切认证,请参阅实际证书):„CE EMC-EN 61326-1„FM FM 3600 FM 3611„CSA CSA C22。2号213-M1987 CSA C22。2号1010-1„ATEX ATEX 94/9/EC EN60079-0 EN60079-15„IEC Ex IEC60079-0 IEC60079-15„海事认证:IACS E10 ABS设计评估证书DNV-GL海事证书„安全认证阿基里斯2级(v13.3.1,v14.FP1*)危险区域/位置EIOC可根据以下标准安装和使用(有关每种产品的确切产品标记,请参见实际证书):„FM(美国)I类2类A、B、C、D、T4组„cFM(加拿大)I类2类A、B、C、D组,T4„ATEX II 3G Ex nA IIC T4 Gc„IEC Ex II 3G Ex nA IIC T4 Gc有关安装说明,请参考以下文件:Class 1 Division 2 Installation instructions DeltaV S Series(12P5402 Zone 2 Installation instructions DeltaV S Series(12P5404)*PRP communications未包含在2021 4月的认证以太网I/O卡(EIOC)中www.emerson。com/deltav 12订购信息描述型号单工以太网输入/输出卡(EIOC)组件,(包括EIOC、双水平载波、通用载波保护盖、2个用于双绞线的以太网隔离端口、2个电源插头)SE4100冗余以太网输入/输出卡(EIOC)组件,(包括2个EIOC、双水平载波、2个用于双绞线的以太网隔离端口、2个电源插头)SE4101用于以太网连接输入/输出(EIOC)的MODBUS TCP接口VE4103用于以太网连接输入/输出(EIOC)的以太网/IP控制标签集成VE4104用于以太网连接输入/输出(EIOC)的以太网/IP接口VE4105用于以太网连接输入/输出(EIOC)的OPC-UA客户端VE4106 IEC 61850 MMS接口以太网连接的I/O(EIOC)VE4107以太网连接的I/O(EIOC和PK):nn物理设备VE4109Sxxx,其中xxx和nn是要在EIOC中许可的物理设备数。VE4109Sxxx许可证是系统范围的,可以分配给EIOC或PK控制器。此外,VE4109Sxxx许可证是系统中的附加许可证,因此,如果您想增加物理设备的数量,只需购买更多许可证即可
1X00126H02重量颜色 1X00126H02重量颜色 1X00126H02重量颜色
Ethernet I/O Card (EIOC) April 2021 www.emerson.com/deltav 11 Certifications The following certifications are available for the EIOC (see actual certificates for exact certifications for each product): „ CE EMC - EN 61326-1 „ FM FM 3600 FM 3611 „ CSA CSA C22.2 No. 213-M1987 CSA C22.2 No. 1010-1 „ ATEX ATEX 94/9/EC EN60079-0 EN60079-15 „ IEC-Ex IEC60079-0 IEC60079-15 „ Marine Certifications: IACS E10 ABS Certificate of Design Assessment DNV-GL Marine Certificate „ Security Certifications Achilles Level 2 (v13.3.1, v14.FP1*) Hazardous Area/Location The EIOC can be installed and used based on the following Standards (see actual certificates for exact product markings for each product): „ FM (USA) Class I, Division 2, Groups A, B, C, D, T4 „ cFM (Canada) Class I, Division 2, Groups A, B, C, D, T4 „ ATEX II 3G Ex nA IIC T4 Gc „ IEC Ex II 3G Ex nA IIC T4 Gc Regarding the Installation instructions please refer to the following Documents: Class 1 Division 2 Installation Instructions DeltaV S-Series (12P5402 Zone 2 Installation Instructions DeltaV S-Series (12P5404) *PRP communications are not included in the certification Ethernet I/O Card (EIOC) April 2021 www.emerson.com/deltav 12 Ordering Information Description Model Number Simplex Ethernet I/O Card (EIOC) Assembly, (Includes EIOC, Dual Horizontal Carrier, Universal Carrier Protection Cover, 2 Ethernet Isolation Ports for twisted copper, 2 Power Plugs) SE4100 Redundant Ethernet I/O Card (EIOC) Assembly, (Includes 2 EIOC, Dual Horizontal Carrier, 2 Ethernet Isolation Ports for twisted copper, 2 Power Plugs) SE4101 MODBUS TCP Interface for Ethernet connected I/O (EIOC) VE4103 EtherNet/IP Control Tag Integration for Ethernet connected I/O (EIOC) VE4104 EtherNet/IP Interface for Ethernet connected I/O (EIOC) VE4105 OPC-UA client for Ethernet connected I/O (EIOC) VE4106 IEC 61850 MMS Interface for Ethernet connected I/O (EIOC) VE4107 Ethernet connected I/O (EIOC and PK): nn Physical Devices VE4109Sxxx Where xxx and nn is the number of Physical Devices that you want to license in the EIOC. VE4109Sxxx licenses are system wide and can be assigned either to the EIOC or PK controller. Also, VE4109Sxxx license is additive in the system and therefore you just need to buy more licenses if you want to increase the number of physical devices



相关产品